Main technical data:
1. Display dimension: 210mm*145mm*48mm
2. Self power consumption: <3W
3. Measuring Accuracy of temperature: ±2℃
4. Temperature range of measuring: 0~150℃
5. Max power of controlled circulation pump: possible to control 4 pumps, every power ≤600W
6. Power of auxiliary electrical booster ≤2000W (standard collocation), ≤3000W (not standard, selection available)
7. Inputs: 6 inputs, Pt-1000 for collector, sensor temperature ≤500℃ (silicon cable ≤280℃), NTC10K,B=3950 for tank, sensor temperature ≤135℃, (PVC cable ≤105℃
8. Outputs: 5 outputs, one for electrical booster, 4 for circulation pump or 3-way electromagnetic valve)
9. Ambient temperature range: -20~60℃
Water protection grade:IP40